principle

The principle of infrared continuous zoom lens

The principle of infrared continuous zoom lens is to use two or more lens groups in the optical system to move in a straight line along the path given by the optical design, changing the combined focal length of the overall optical system, while keeping the position of the image surface unchanged, and the image always remains clear during the continuous zoom process.

Module

The lens group of the infrared continuous zoom system can be divided into several modules

Front fixed mirror group: the maximum clear aperture is determined by the design parameters, and its function is to provide a fixed image to the optical system;

Zoom group: it is a group of lenses that move linearly to change the focal length of the optical system;

Compensation mirror group: a group of lenses do nonlinear linear motion, and the offset of the image plane affecting the whole image surface during the movement of the zoom group is compensated;

Post-fixed group: Used to convert the image of the compensation group into a real image, and adjust the focal length value of the overall synthesis and the aperture diaphragm of the optical system.

 

Usually in the infrared zoom design, the micro-movement of the zoom lens group and the compensation mirror group is fitted into two curves according to the data points, and reflected in the cam of the structural design, the processing accuracy of the cam curve will directly affect the overall imaging quality, so the higher the accuracy of the cam curve processing, the better, and the denser the data points given by the cam curve, the better.

In addition, the post-fixation group introduced above is not fixed in practical application, due to the cumulative error of the lens and lens base, the imaging surface of the overall image will not be ideal, so in the actual use of the first correction, a small amount of adjustment is required to make the imaging surface and the FPA of the detector match.